Products
Thermal mass flow meter
PBF-Q7212 Pipe flange
2024-06-191355


Pipe flange installation is mainly used for measuring the mass flow rate of fluid with smaller diameters than Ø65, 

and to improve its measurement accuracy. A flow meter is connected with field pipe by flange together with double 

snap rings and ten layers PTFE sealing rings. It is can bear much higher pressure and easy for maintenance.


 

Specifications: 

 

Flow range

 0.4-60m/s,0.4-80m/s(velocity of flow)

Accuracy

 ±1.0%FS , ±1.5%FS

Repeatability

±0.2%FS

Response time

< 100 ms

Sensitivity

< 0.05 m/s

Flow temperature

-20~+120℃、-20~+200℃、-20~+300℃

Ambient temperature

-20~+55℃

Working pressure

0~0.8MPa 、0~2.5MPa 、0~5.0MPa

Explosion Protection

dⅡCT2~6

Ingress Protection

IP65

Power supply

18-24VDC、I≥350mA,optional:220VAC 

Output

4~20mA、optional:RS485、HART

Sensor material

316L,