Products
Thermal mass flow meter
PBF-Q6212 Insertion
2024-06-191419

It is recommended use insertion installation when the pipe size is larger than Ø65. 

By using this kind of installation together with globe valve structure, 

meters can be installed without interrupting flow. 



Specifications:

 

Flow range

 0.4-60m/s,0.4-80m/s(velocity of flow)

Accuracy

 ±1.0%FS , ±1.5%FS

Repeatability

±0.2%FS

Response time

< 100 ms

Sensitivity

< 0.05 m/s

Flow temperature

-20~+120℃、-20~+200℃、-20~+300℃

Ambient temperature

-20~+55℃

Working pressure

0~0.8MPa 、0~2.5MPa 、0~5.0MPa

Explosion Protection

dⅡCT2~6

Ingress Protection

IP65

Power supply

18-24VDC、I≥350mA,optional:220VAC 

Output

4~20mA、optional:RS485、HART

Sensor material

316L,